34 AWG wire size

0.16 mm · 0.02 mm²

0.0063 in diameter · 855.905 Ω/km in copper

What 34 AWG is used for

Transformer and motor coil winding.

The numbers

Diameter0.16 mm · 0.0063 in
Cross-sectional area0.0201 mm²
Resistance, copper855.905 Ω/km · 260.88 Ω per 1,000 ft
Resistance, aluminium1400.031 Ω/km
NEC 60 °C copper ampacityoutside the common building-wire range

How 34 compares

The gauge scale is geometric, so the useful comparisons are ratios rather than differences. 28 AWG is twice the diameter, which is four times the area.

GaugeDiameterAreaΩ/km coppervs 34
280.321 mm0.081 mm²212.94.02× the area
300.255 mm0.051 mm²338.532.53× the area
320.202 mm0.032 mm²538.281.59× the area
360.127 mm0.013 mm²1360.940.63× the area
380.101 mm0.008 mm²2163.980.4× the area
400.08 mm0.005 mm²3440.870.25× the area

Frequently asked questions

What is 34 AWG in mm?

0.16 mm in diameter (0.0063 inches), with a cross-sectional area of 0.02 mm².

Is 34 AWG used for power wiring?

Not for building circuits. It is a signal and low-current gauge — thinner than anything a domestic branch circuit uses.

What is the resistance of 34 AWG copper?

855.905 Ω per kilometre, or 260.88 Ω per 1,000 feet, for annealed copper at 20 °C. The same gauge in aluminium is about 1400.03 Ω/km — 1.64 times higher, which is why aluminium wiring is sized larger for the same load.

Why do smaller AWG numbers mean thicker wire?

The number counts drawing operations. Wire is pulled through progressively smaller dies, and the gauge records how many passes it took — so more passes means a higher number and a thinner wire.