32 AWG wire size

0.202 mm · 0.032 mm²

0.008 in diameter · 538.284 Ω/km in copper

What 32 AWG is used for

Coil winding and fine electronics work.

The numbers

Diameter0.202 mm · 0.008 in
Cross-sectional area0.032 mm²
Resistance, copper538.284 Ω/km · 164.069 Ω per 1,000 ft
Resistance, aluminium880.488 Ω/km
NEC 60 °C copper ampacityoutside the common building-wire range

How 32 compares

The gauge scale is geometric, so the useful comparisons are ratios rather than differences. 26 AWG is twice the diameter, which is four times the area.

GaugeDiameterAreaΩ/km coppervs 32
260.405 mm0.129 mm²133.94.02× the area
280.321 mm0.081 mm²212.92.53× the area
300.255 mm0.051 mm²338.531.59× the area
340.16 mm0.02 mm²855.910.63× the area
360.127 mm0.013 mm²1360.940.4× the area
380.101 mm0.008 mm²2163.980.25× the area

Frequently asked questions

What is 32 AWG in mm?

0.202 mm in diameter (0.008 inches), with a cross-sectional area of 0.032 mm².

Is 32 AWG used for power wiring?

Not for building circuits. It is a signal and low-current gauge — thinner than anything a domestic branch circuit uses.

What is the resistance of 32 AWG copper?

538.284 Ω per kilometre, or 164.069 Ω per 1,000 feet, for annealed copper at 20 °C. The same gauge in aluminium is about 880.49 Ω/km — 1.64 times higher, which is why aluminium wiring is sized larger for the same load.

Why do smaller AWG numbers mean thicker wire?

The number counts drawing operations. Wire is pulled through progressively smaller dies, and the gauge records how many passes it took — so more passes means a higher number and a thinner wire.