24 AWG wire size

0.511 mm · 0.205 mm²

0.0201 in diameter · 84.208 Ω/km in copper

What 24 AWG is used for

Ethernet and telephone pairs, ribbon cable, most hookup wire.

The numbers

Diameter0.511 mm · 0.0201 in
Cross-sectional area0.2047 mm²
Resistance, copper84.208 Ω/km · 25.667 Ω per 1,000 ft
Resistance, aluminium137.742 Ω/km
NEC 60 °C copper ampacityoutside the common building-wire range

How 24 compares

The gauge scale is geometric, so the useful comparisons are ratios rather than differences. 18 AWG is twice the diameter, which is four times the area.

GaugeDiameterAreaΩ/km coppervs 24
181.024 mm0.823 mm²20.954.02× the area
200.812 mm0.518 mm²33.312.53× the area
220.644 mm0.326 mm²52.961.59× the area
260.405 mm0.129 mm²133.90.63× the area
280.321 mm0.081 mm²212.90.4× the area
300.255 mm0.051 mm²338.530.25× the area

Frequently asked questions

What is 24 AWG in mm?

0.511 mm in diameter (0.0201 inches), with a cross-sectional area of 0.205 mm².

Is 24 AWG used for power wiring?

Not for building circuits. It is a signal and low-current gauge — thinner than anything a domestic branch circuit uses.

What is the resistance of 24 AWG copper?

84.208 Ω per kilometre, or 25.667 Ω per 1,000 feet, for annealed copper at 20 °C. The same gauge in aluminium is about 137.74 Ω/km — 1.64 times higher, which is why aluminium wiring is sized larger for the same load.

Why do smaller AWG numbers mean thicker wire?

The number counts drawing operations. Wire is pulled through progressively smaller dies, and the gauge records how many passes it took — so more passes means a higher number and a thinner wire.